When the transformer operates in the power system, it is difficult to avoid some short-circuit events. Depending on the severity of the short-circuit event and the strength of the transformer's anti short-circuit ability, sometimes it is safe and sometimes it is damaged. The damage of a distribution transformer will affect a factory in a short time, while the short-circuit accident of a distribution transformer will affect an urban area, and the replacement is more difficult, and the repair takes 2 3 months. Therefore, improving the short-circuit resistance of power transformer has always been a matter of great concern to the power department, and it is also the main goal of the manufacturing department.
Before the 1990s, there were only four high current laboratories (stations) in Xi'an, Shenyang, Shanghai and Beijing in China. Their facilities are mainly for switching capacity test in the switching industry, but they can also test distribution transformers. Therefore, in the early and mid-1980s, Shenyang
Transformer Research Institute a fost responsabil pentru proiectarea unificată a transformatoarelor de distribuție sl7 și vechi s9-30 1600KVA/10kV. Proba prototipurilor produse de fiecare fabrică a efectuat teste de scurt{12}}circuit în laboratoarele (stațiile) de mai sus. 14 sl7 și 12 vechi S9 au trecut testele. După succesul testului, noul tip S9 a fost produs de probă. Primul lot de 37 de unități a trecut testul, iar rata de calificare a noului tip S9 a ajuns la peste 90% (Kema din Olanda a testat transformatoare de distribuție străine, cu o rată de calificare unică de 50%). Până în 1996, aproximativ 300 de transformatoare de distribuție fuseseră testate în diferite laboratoare (stații), inclusiv de tip S7.
For more than ten years, China has done a lot of short-circuit tests on distribution transformers, and improved each damage condition, so that the qualified rate reaches more than 90 percent , much higher than the foreign qualified rate of 50 percent , which has been confirmed in the actual operation of power grid and achieved gratifying results. It can be said that the basic solution to the short-circuit strength of distribution transformer depends on "practical test", which is a very important experience.
Nu există o bază pentru testarea transformatoarelor de putere în China, așa că rezistența la scurt-circuit a transformatoarelor de putere este dificil de rezolvat. În 1986, Comisia de Stat de Planificare a aprobat construcția stației de testare cu curent înalt Shenyang Hushitai, care a fost împrumutată de stat și aprobată pentru a fi consultată de compania EDF din Franța. După mulți ani de muncă, prima fază a proiectului a fost finalizată la sfârșitul anului 1993, a fost construită o rețea de 220 kV și au fost instalate două 1200 mva / 0 224 kv. După acceptarea de către comitetul de experți de stat, acesta a fost pus în funcțiune în ianuarie 1994 și au fost efectuate un număr mare de teste de transformatoare de distribuție în 1994 și 1995. După dobândirea experienței, testul de scurt-circuit al transformatorului de putere de 110kV a fost realizat în 1996.
Test de scurtcircuit al transformatorului de putere de 110kV
110kV power transformer is the main transformer in China's transmission and distribution system, and its output accounts for about 1 / 5 of the total output of transformer. According to the statistical data from 1995 to 1996, the short-circuit accident of 110kV transformer accounts for 5O percent of the total accident of this level, and shows an upward trend. Therefore, how to improve the short-circuit resistance of this level of power transformer has become the main topic at the Zengcheng conference in Guangdong. It is recognized that the best way is to verify it with short-circuit test.
From 1996 to the first half of 2005, due to the attention of power departments and manufacturing enterprises, More than 60 factories have successively conducted short-circuit tests on 80 110kV power transformers (including 4 from Shenyang Transformer Co., Ltd., 3 from Xinjiang TBEA Co., Ltd., 2 from Nantong AIA Transformer Co., Ltd., 2 from Changzhou transformer factory, 3 from Yunnan Transformer Factory, 2 from Baoding, 3 from Huapeng, etc.) with a pass rate of >96 la sută. Transformatoare de distributie cu rata de calificare mai mare de 10kV.
Pentru a trece primul test, aceste fabrici au investit foarte multe resurse umane și materiale. În procesul de dezvoltare a produsului, ei au depus anumite eforturi în proiectare, proces, producție și management, ceea ce reprezintă, fără îndoială, o mare îmbunătățire a calității globale a întreprinderilor. 28 din cele 45 de produse testate in prima jumatate a anului 2001 functioneaza pe reteaua electrica, iar cel cu cel mai scurt timp de functionare functioneaza de cateva luni. Printre acestea, un nou produs al stației Shenyang, transformatorul de 50000kVA / 110kV, funcționează de mai bine de cinci ani și este binevenit de utilizatori. Pe baza obținerii datelor de testare, aceste fabrici au îmbunătățit structura de proiectare a produsului. Luând acest lucru ca standard, acestea au fost introduse în producție de masă și introduse în rețeaua de energie electrică, astfel încât nu vor exista accidente de scurt-circuit în viitor.
Datele statistice ale Wuhan High Voltage Research Institute of State Power Corporation și China Electric Power Research Institute din 1995 până în 1999 arată că accidentul de scurt-circuit al transformatorului a scăzut de la 50% în trecut la 40%, ceea ce este în principal datorită îmbunătățirii fiabilității funcționării sistemului datorită funcționării lotului de mai sus de transformatoare foarte fiabile. Trebuie spus că accidentul de scurt-circuit al transformatorului de 110 V a fost inițial redus.
Testul de scurt-circuit al transformatorului de 110 kV ar trebui extins în continuare
În prezent, există 60 de fabrici care furnizează în mod normal transformatoare de putere de 110 V în China și doar peste 100 de fabrici au efectuat teste de scurt-circuit de transformator de 110 kV, reprezentând aproximativ 55 la sută . Câteva fabrici pregătesc condiții pentru testul de scurt-circuit, care necesită sprijin puternic din partea utilizatorilor și adoptă în mod activ produsele testate pentru a juca un rol în sistem. În ceea ce privește fabricile de producție, ar trebui să desfășurăm lucrări din punct de vedere al designului și tehnologiei, să facem suficiente pregătiri materiale, să strângem fonduri și să le punem în practică. De asemenea, trebuie subliniat faptul că fabricile care nu au făcut teste de scurt-transformator trebuie să profite de timp, pentru a nu afecta comanda și chiar a pierde calificarea producției.